Operating Specifications |
|
| Flow range | 0.5 to 50 gpm |
| Pressure range | 20 to 150 psi (1.5 to 10 bars) |
| Temperature range | Up to 150°F (66°C) |
Electrical Specifications | |
| Solenoid power | 24 VAC 50/60 cycle |
| 0.43 amp | (10.4 VA) inrush current |
| 0.25 amp | (6.0 VA) holding current |
| Pressure
Loss (PSI) MVA®-100 |
|
|---|---|
FLOW-gpm |
HEADLOSS-psi |
| 0.50 | 1.8 |
| 1.00 | 2.5 |
| 5.00 | 2.0 |
| 10.00 | 2.1 |
| 20.00 | 3.6 |
| 30.00 | 7.1 |
| The foregoing figures are based on tests run on a 6-valve Multi-Valve Assembly, then calculated to reflect single-valve loss.
Shaded area designates recommended operating range. Performance results are derived from tests conducted by an independent testing laboratory, Center for Irrigation Technology (CIT), California State University, Fresno, California. | |
Angle Globe Valve: AGV-100-UTL, Low-Cost Utility Series |
||
Single 1 inch valve, 24 VAC solenoid, 150 psi |
||
![]() |
![]() |
8121 8121-F |
| 8121-F | 8121 | |
| Operating Specifications | Electrical Specifications | Pressure Loss (PSI) - MVA-100 | How to Specify | ||
Dual-Valve Assembly: DVA-100-UTL,
|
||
Two AGV-100-UTL valves, 1inch, 24 VAC solenoids, 150 psi, pre-assembled in a 10 inch round valve box |
||
![]() |
![]() |
8127 8127-F |
| 8127-F | 8127 | |
| Operating Specifications | Electrical Specifications | Pressure Loss (PSI) - MVA-100 | How to Specify | ||
|
|
||
How to Specify |
||
| Assembly | AGV | Angle Globe Valve |
| DVA | Dual Valve Assembly | |
|
|
||
| Valve Size | 100 | 1 inch |
|
|
||
| Valves | 4 | Number of Valves |
|
|
||
| Series | UTL | Utility |
| PRO | Professional | |
| PRO-N | Professional, Non-Wired | |
|
|
||
| Optional Features | FLO | Flow Control |
| N | No Box | |
|
|
||
| Lid Color | P | Purple |
|
|
||
| U.S. Patents 6,460,563, D402,635 | ||
|
|
||